Long-term energy-efficient heating
Heat Pump Installation in Eton, Planned for a Conservation Town
Heat pump installation in Eton means working inside a conservation area first designated in 1971, in a town whose neighbourhood plan counts over 90 listed buildings. We calculate each room’s heat loss, fix where the outdoor unit stands and how the pipes get in, then put design and price in writing before a single order. MCS certified, with the £7,500 BUS application filed by us.
Featured project: Viessmann Vitocal 150 on two mixed circuits in a 1960s Maidenhead house with patchy insulation, now holding 21°C room to room.
“We moved out while Adam spent a week fitting the heat pump and upgrading radiators and felt very happy leaving him in the house to do everything he needed to do.”
Lucy Grainger,
Google Review
Before you book
What Eton Homeowners Ask Us Before They Commit
Eton parish holds two different housing stocks on the same flat Thames floodplain. Behind the High Street, 19th-century terraces on Tangier Lane and Sunbury Road front the pavement, with small gardens and alleys at the back. West along Eton Wick Road, the village grew from the 1880s streets of Boveney Newtown to closes built in the 1960s and 70s. Across the river we also cover Windsor.
You may be wondering:
With the street front ruled out for the outdoor unit, is there room left on a narrow terrace plot?
If the house is listed, which consents does it need, and how much time do they add?
If the Thames comes up, what happens to a unit standing in the garden?
Should a bedroom still run cold after the first hard frost, whose job is it to put right?
Eco Renewables handles air-to-water heat pump installation in Eton by settling those questions at survey: unit position against the planning rules for your address, the flood risk the survey finds there, and a heat loss figure for walls that might be 200 years old or 50. Your Heat Pump Blueprint holds all three, costed, before a part is ordered.
Featured project: Installation of Viessmann Vitocal 150 With Mixed Circuits
Why Eco Renewables
Why Eton Homeowners Choose Us
Siting planned to the rules
In the conservation area, permitted development keeps the unit off any wall or roof fronting a highway, so we plan a rear position first.
Heat loss worked room by room
A 19th-century Tangier Lane terrace, typically solid brick, and a 1960s Eton Wick close, typically cavity wall, get separate calculations.
Flood risk checked at survey
We look up your address on the Environment Agency flood map and plan the unit’s position around what it shows.
£7,500 BUS grant handled
We make the application and confirm eligibility at survey.
Manufacturer picked from your numbers
Viessmann, Vaillant or Grant, chosen from the heat loss figures.
Your engineer stays on the phone
12 months’ direct support after every Eton installation, plus the first annual service.
What Our Clients Say
Eco Renewables are trusted by homeowners throughout Surrey and the South East to provide high-quality heat pump heating system installations.
How it works
Our Simple 3-Step Process
Your Heat Pump Blueprint
Inside Your Free Heat Pump Blueprint
Your Blueprint puts the design for your house on paper before you commit to anything. Put it next to any other quote and compare the two line by line.
1
Room-by-room heat loss
The calculation covers each room on its own, and we size the heat pump to the total for your house.
2
Radiator schedule
We check each radiator against its room at the design flow temperature. The schedule lists and prices any that fall short, so a swap can’t turn up later as an extra.
3
Flow temperature plan
This sets the design flow temperature and the weather compensation curve your system runs on. Where underfloor heating needs a different temperature from the radiators, mixing groups split the circuits.
4
Hot water plan
The plan sets the cylinder size for your household and where it sits, often the airing cupboard or loft when a combi leaves no hot water store.
5
Scope and fixed price
Unit, radiators, pipework, cylinder and controls sit under one fixed price, with the BUS grant and what’s left to pay shown beneath it.
I contacted a number of companies and had read up extensively on heat pumps before going ahead with Adam of Eco Renewables so I was confident in choice of installer, however you never really know if you have made the right decision until it’s all up and running and your home is no longer cold.
Andrew Symes
Google Review
Grants and VAT
Grants and Savings for Heat Pump Installation in Eton
£7,500
BUS grant
Through the Boiler Upgrade Scheme, a qualifying air source heat pump in an Eton home attracts a £7,500 grant, which comes off the invoice. The property must be yours, the heating it replaces must burn fossil fuel, and the installer must be MCS certified. We check your eligibility at survey and make the application.
0%
VAT to March 2027
The work is also zero-rated: 0% VAT through March 2027 on qualifying installations, so no VAT sits on an Eton heat pump price.
Before you commit, the Blueprint lists the full price, the grant coming off it and the balance left to pay. Our 2026 heat pump cost guide shows typical spend by property size.
Case study: Maidenhead
Real Life-Changing Results
This Maidenhead renovation involved redesigning the heating system in a complex 1960s home using a Viessmann heat pump to deliver a perfectly balanced 21°C throughout the house despite mixed insulation levels and constrained underfloor heating upstairs.
The property had very different heat losses across rooms and strict floor height limits for upstairs underfloor heating. Instead of forcing the whole system to run at one compromise temperature, we engineered separate flow temperatures using mixing groups so every zone could perform properly. The result is consistent comfort throughout the house and a system that runs efficiently and predictably.
“What we appreciated most was that nothing was rushed. The numbers were checked properly and the system was designed around the house rather than the other way around. The temperature is consistent throughout and we can fine-tune it easily. It feels engineered, not just installed.”
Homeowner, Maidenhead
See Our Work First-Hand
Conservation-area rules in Eton keep the unit off any wall fronting the road, which leaves the rear yard behind a Tangier Lane terrace. The wall-bracket unit below shows how little ground that takes, and the cylinder photos help where cupboard space runs short. Downriver past Windsor, we plan Old Windsor heat pump installs around glazed rear extensions, which can need their own underfloor loop.
Heat pumps
Underfloor heating and hot water
Aftercare
Our Guarantees for Eton Homeowners
5-year workmanship guarantee on every installation
Insurance-backed deposit and 2-year workmanship cover
Manufacturer warranty on equipment
Lifetime system monitoring included
Direct access to your Heat Geek trained engineer, not a call centre
First annual service included with every heat pump installation
Single point of accountability: BUS grant, registration and post-install issues all come to us
Our job as the air source heat pump installer in Eton runs through your first year, with 12 months of support and the first annual service. We hold every job to it as a heat pump installation company in Eton, as we do across our wider Berkshire service area.
Eton FAQs
Common Questions About Heat Pump Installation in Eton
Expect £10,000 to £18,000 on an air source heat pump installation in Eton, before the grant comes off. A small Tangier Lane terrace sits toward the lower end; a larger listed house needing radiator upgrades and consent work sits higher. Your Blueprint gives the exact figure before you sign.
Expect 2 to 4 days of site work for an Eton installation. Drilling thick old brick for pipework can add a day. For a listed building, the council’s consent decision comes first and can take several weeks, so we build that into the timeline you get at Blueprint stage.
In Eton Wick, outside the conservation area, a unit can be permitted development under the May 2025 rules, within conditions such as the 1.5 cubic metre size limit and MCS noise standard. In the Eton Conservation Area it must also stay off any wall or roof fronting a highway, and no nearer that highway than the house. The full conditions are in our guide to heat pump planning rules.
Often, once consent is in place. Permitted development doesn’t apply to a listed building or its grounds, so a listed Eton house needs planning permission, plus listed building consent where the work affects its character, such as new holes through historic walls. We flag what consent the property needs at survey, build it into the plan, and keep the unit position and pipe routes low-impact.
Two checks decide it in Eton: a lawful spot for the outdoor unit and enough indoor space to house a hot water cylinder. A terrace with a rear yard or alley often has the first; the survey confirms both for your address and tells you if either fails.
The Boiler Upgrade Scheme is worth £7,500. An Eton owner qualifies when fossil-fuel heating is being replaced and the work is done by an MCS certified installer. Eligibility gets checked on the survey visit, and zero-rated VAT applies to qualifying work until the end of March 2027.
It depends on each room. At survey we compare each radiator’s output with the heat loss of its room at a heat pump’s lower flow temperatures. Where one falls short, the Blueprint names the replacement and prices it, and your Eton install day adds nothing to that.
Boiler to heat pump in Eton means sizing the heat pump, radiators and cylinder to the house’s heat loss, then taking the gas boiler out. The survey shows whether the heat pump is enough on its own for the house, and the Blueprint lists the cylinder and pipework changes involved.
The Eton and Eton Wick Neighbourhood Plan records that most of its area intersects Flood Zones 2 or 3. The survey checks the Environment Agency flood map for your address, and the Blueprint shows where the unit sits and how high its base needs to be for that risk, still off any street-facing wall in the conservation area.
They cost what the design and setup allow. Commissioned to its Blueprint, with weather compensation switched on and a heat pump tariff like Cosy Octopus, an Eton system can undercut the running cost of the gas boiler it replaces. Left on factory settings, the same unit costs more, which is why every Eton handover covers the tariff and the controls.
Yes. In an Eton installation one hot water cylinder serves both heating and taps, sized to your household’s demand. Where cupboard space is tight in an older house, the Blueprint shows where the cylinder goes before you commit.
Before we order a single part you hold the Heat Pump Blueprint: room heat losses, radiator sizes, the flow temperature and the hot water plan. Each Eton installation is commissioned to that document and to Heat Geek standards.
The whole of Eton parish is on our patch, from the listed houses off the High Street and the 19th-century terraces on Tangier Lane and Sunbury Road to Eton Wick, about a mile and a half west along Eton Wick Road. That takes in the 1880s streets of Boveney Newtown and the 1960s and 1970s closes beyond them, and we also work in Windsor, just across the Thames.
Get a Heat Pump Survey for Your Home
If getting an air source heat pump is on your mind, we’re more than happy to talk through your property and system options with you.
Heat loss of each room
Radiator sizes
Flow temperatures
Hot water plan
Get a Solar or Heat Pump Survey & Design Consultation
If you’re considering a heat pump, the survey is where it starts. We assess the property, run the heat loss calculations, and tell you exactly what the system would look like before you commit to anything.
Get My Free Heat Pump Blueprint