Mechanical ventilation with heat recovery
MVHR Installation in Berkshire & Surrey: Fresh Air In, Your Heat Kept
An airtight house holds its heat, and its steam, smells and CO2. Our MVHR installation brings in filtered fresh air and keeps the warmth, from Binfield across Berkshire, Surrey and Buckinghamshire.
Five Years a Customer: Knowledge, Care and a Trader Who Never Lets Us Down
“You rarely meet people who are so knowledgable and passionate about their trade – but this guy genuinely is. Very responsive and trustworthy. We have been customers of Adam for over 5 years and he has never failed us yet!”
Adam Hewitt,
Google Review
Before you book
Questions Homeowners Ask Before an MVHR Installation
MVHR runs day and night, and its ducts disappear into your ceilings for good.
You may be wondering:
Will I hear it from the bedroom?
Can my house take the ducts?
Will the air stay fresh with windows shut?
Who changes the filters, and how often?
They’re the right questions for a system you’ll live with every hour of the day.
Our MVHR installation work starts with a ventilation design drawn for your house, and that design settles all four questions before any ducting goes in.
The short answers
Airtight Homes Need Mechanical Ventilation, and Heat Recovery Keeps the Heat
Build or renovate tighter than 5 m³/(h·m²) at 50 Pa and Approved Document F looks for continuous mechanical ventilation. Heat recovery keeps the warmth: one unit extracts from the wet rooms, supplies the living spaces and passes the heat across.
Quiet in the bedroom
Fans sized to run well below full speed, inside the 30 dB Approved Document F sets for bedrooms. We check low and boost before handover.
A route for the ducts
Easiest in a new build, extension or renovation. MVHR retrofit needs a route through the loft, floor voids or boxing, and the survey finds it.
Fresh air with the windows shut
It runs day and night at a low rate, boosts for showers and cooking, and the fresh air arrives already warmed.
Filters you can reach
We fit the unit where you can open it and change a filter in front of you at handover. Zehnder: inspect every 16 weeks, replace every six months.
Illustrative visualisation
Why Eco Renewables
Six Reasons Homeowners in Berkshire and Surrey Choose Us for MVHR
Six things you get when we design and fit your MVHR system.
Specialist ductwork design
A dedicated ventilation design company draws the layout and sizes the unit.
Zehnder experience
We fit Zehnder MVHR units on developer projects, each one sized and ducted to its own design.
Commissioned to the design
We measure the design flow rate at every supply and extract valve and record the readings on your commissioning sheet.
Heating and ventilation designed together
A Heat Geek trained engineer sizes your heat pump with the ventilation in the heat loss calculation.
Timed around your builder
We plan the first-fix ducting into your build programme while the ceilings and floors are open.
One accountable company
Gas Safe roots, plus MCS certification for our heat pump work.
Follow the Air From a Steamy Bathroom to a Fresh Bedroom
One unit, often up in the loft, swaps stale air for fresh and hands the warmth across. Scroll to follow a loop of air through the house, with a marker on each part that matters, then see the design we draw up before any ducting goes in.









- Kitchen (extract)
- Bathroom (extract)
- En-suite (extract)
- Living room (supply)
- Main bedroom (supply)
- Bedroom two (supply)
Two openings, set apart
The loop starts and ends on the gable. Fresh air comes in through one terminal and stale air leaves through the other, set well apart so the unit never draws its own exhaust back in.
Steam out
Straight after a shower, the steam heads for a small round valve in the bathroom ceiling. It extracts all the time at a low rate and turns up for showers.
Cooking smells out
The kitchen has its own extract valve, set to the side of the hob. It runs all the time and boosts while you cook.
One duct to each room
Each valve has its own duct back to a plenum box, so the airflow to every room can be set on its own. From the plenum the ducts drop into the joist bays and run buried in the loft insulation, so the air stays warm.
One box does the work
The unit sits on anti-vibration feet on a boarded platform, with room to open it for filter changes. A trapped drain carries away the water it collects.
Insulated all the way to the wall
Two larger ducts run from the unit to the gable terminals, wrapped in insulation so cold outdoor air never drips condensation into the loft.
The heat changes hands
In a typical unit, outgoing warm air heats the incoming cold air through thin plates, and the two streams never touch. Filters clean the air on both sides.
Fresh air in
By morning the bedroom has had fresh air all night, with the window shut against the frost. Its supply valve was balanced to the design flow at commissioning.
Fresh air where you sit
The living room has its own supply valve, balanced like the bedrooms, so the evening air stays fresh with every window shut.
Your ventilation design
We work out the airflow for each room, the duct route, and where the unit and the two gable terminals go. You see the layout and a written quote before you commit.
Designed for your house
See every duct and valve planned before first fix
Your survey sets the airflow for each room, the duct route and where the unit and the two gable terminals go, with a written quote before you commit.
What Our Clients Say
Homeowners across Berkshire and the South East on working with Adam.
Local MVHR installers
MVHR Fitted and Commissioned by an Installer Near You
We plan and fit MVHR within reach of our Binfield base, with the first-fix ducting timed into your builder’s programme.
Air flow measured at every valve
We measure the flow rate at every supply and extract valve and record the readings on your commissioning sheet.
Filter change shown at handover
We change a filter in front of you at handover and leave the maintenance schedule for your unit and its filters.
Servicing set out at the survey
We fit the unit with clear space in front of its filter doors and set out servicing options for your system at the survey.
Check you’re in our area
Type your postcode and we’ll tell you straight away if your home is one we cover.
Where we work
Popular areas
How it works
Our MVHR Installation Process
You see the design and a written quote before any ducting goes in.
Initial Consultation
Tell us about the project: new build, extension, renovation or a finished house, the stage you’re at, and any airtightness target your architect or builder has set. Send plans if you have them.
Book My Survey & QuoteSurvey and Ventilation Design
Adam checks where the unit can live, how ducts can reach each room and where the intake and exhaust can leave the building. Our design partner then draws the duct layout and sizes the unit, and you get a written quote.
Installation
On a build, first fix puts the ducts and valve positions in while the structure is open, often alongside underfloor heating pipework. Second fix brings the unit, valves, condensate drain and controls.
Commissioning and Handover
Handover starts once the system meets its design flow rates, with the noise checked on the low and boost settings. You then get a walkthrough of the controls and the filter change.
MVHR Installation Cost
MVHR system cost depends on your house first and the unit second. We quote from the survey and the ventilation design, so the figure reflects the ductwork your house needs.
MVHR does not qualify for the Boiler Upgrade Scheme. Paired with an eligible air-to-water heat pump, the grant (£7,500 for most air source installs, subject to eligibility) applies to the heat pump alone, and new builds are excluded apart from qualifying self-builds. Our Boiler Upgrade Scheme guide explains who qualifies.
| What sets the price | Lower end | Higher end |
|---|---|---|
| Floor area and rooms | Fewer rooms, smaller unit | More rooms, more valves |
| Duct route | Open joists in a build | Loft, floor voids or boxing |
| Unit and extras | Standard unit and controls | Passivhaus unit, acoustic extras |
Your written quote follows the survey and the ventilation design.
Your ventilation design
Inside Your MVHR Design
The design puts every duct, valve and airflow figure on paper before anyone drills a hole. Adam surveys the house, and our specialist ventilation design company draws the layout from your plans.
1
Airflow rates, room by room
Supply air is shared across the bedrooms and living rooms by volume, and each wet room gets its own extract rate, following Approved Document F.
2
Duct route
The runs are short and direct, with as few bends as the structure allows, and insulated wherever they cross a cold loft.
3
Unit location
The unit goes where you can open it and swap filters, with a trapped condensate drain away from it.
4
Intake and exhaust
The two outside terminals sit far enough apart that stale air never finds its way back in.
5
Noise
The fans are sized to run well below full speed on the everyday setting, inside the 30 dB Approved Document F sets for bedrooms and living rooms.
6
Commissioning and balancing
We measure the air at every supply and extract valve against the design flow rate, then record the readings on your commissioning sheet.
Results you can check
MVHR Commissioning Results You Can Check on the Day
Every valve
measured against its design flow rate
Low and boost
noise checked on both settings
In writing
readings on your commissioning sheet
New dwellings
measured flows sent to building control
You see the result at commissioning. We measure the air at each supply and extract valve, set the low and boost rates, and hand you the readings before we leave. If a room falls short of its design figure, we adjust it until it meets that figure.
Aftercare
Your MVHR Handover Pack and Filter Changes
Approved Document F asks installers to leave you enough information to run and maintain the system. At handover you get:
The commissioning sheet with the measured air flow at each valve
The design flow rates and a maintenance schedule for the unit and its MVHR filters
A walkthrough of the controls, including boost, and a filter change done in front of you
The manufacturer’s literature for your unit
The filters are the one job that comes round every few months. We fit the unit with clear space in front of its filter doors, and we’ll set out servicing options for your system at the survey.
FAQ
MVHR Installation FAQs
Yes. MVHR, heat recovery ventilation and mechanical ventilation with heat recovery all describe one whole house ventilation system. A single unit extracts stale air from the wet rooms, supplies filtered fresh air to the living spaces and passes heat between the two streams through a heat exchanger.
In an airtight new build or deep renovation, yes. It controls humidity and air quality without opening windows and losing heat, and Approved Document F notes that MVHR performs better as a house gets more airtight. In a draughty older house with no airtightness work planned, the case is weaker, and a survey in Berkshire or Surrey shows which side of that line your house sits on.
We can talk through the likely scope once we know the floor area, the number of rooms and whether the ducts go in during construction or into a finished house. The written quote follows the survey and ventilation design, because duct routes and room count set most of the MVHR cost.
Yes, where the house allows a duct route. MVHR retrofit needs a path for the ducts through the loft, floor voids or boxing, and a house airtight enough to benefit, so it suits deep renovations best, when ceilings or floors are open anyway. Older properties need fabric and airtightness work first, the same thinking behind our guide to heat pumps in older homes.
Yes. Zehnder recommends inspecting MVHR filters every 16 weeks and replacing them every six months. Blocked filters make the fans work harder and cut the air reaching your rooms, so keep a spare set in the cupboard and a change never waits on a delivery.
It does. Beyond filter changes, MVHR servicing covers the fans, the heat exchanger, the valves and the condensate drain, plus a check that the flow rates still match your commissioning sheet. Ask about servicing at your survey and we’ll set out the options for your system in your part of Berkshire, Surrey or Buckinghamshire.
It will, and the two belong in one design. MVHR lowers the ventilation heat loss, which changes the figure we use to work out your heat pump size. We assess both at the same survey, so your heat pump matches the house with the ventilation running.
We’re MVHR installers based in Binfield, near Bracknell, and we work across Berkshire, Surrey, Buckinghamshire and the edge of Greater London, including Wokingham, Ascot, Windsor, Maidenhead, Reading, Guildford and Woking. If your town isn’t on that list, ask when you book.
Get Your MVHR Survey and Quote
Tell us about the house and the stage your project is at. Plans help if you have them.
Your Design, Before First Fix
Bring your plans to the survey, and Adam will talk you through where the unit, ducts and valves could go.
Book My Survey & Quote