Heat pump sizing calculator UK
Air Source Heat Pump Sizing Calculator: Your Heat Loss in kW
You’ll get a heat loss range in kW and the heat pump sizes that cover it, from six questions about your home. This air source heat pump sizing calculator uses the MCS design temperatures for Berkshire, Surrey and the rest of the South East.
Featured project: a 13kW Viessmann Vitocal 150 in a 1960s Maidenhead home, holding 21°C in every room despite uneven insulation
“Adam’s experience and understanding of heatpumps and the all important heat loss calculations was evident from first contact.”
Andrew Symes,
Google Review
Heat pump size calculator
Use the Air Source Heat Pump Sizing Calculator
Answer six questions about the house. The heat loss range and the likely size update as you go.
Your estimate
Estimated heat loss3.9 to 5.3 kW
Central estimate 4.6 kW, about 48 W per m²
A heat pump in the 4 to 6 kW range is likely.
Fix the highlighted answer to update the estimate. The figures above are from your last valid answers.
Planning insulation or new windows? Get that work done first. Adam won’t fit a heat pump that ends up too big once the house changes.
Switch insulation to Improved above to see the drop: 3.7 kW instead of 4.6 kW.
This is an estimate from averages. A heat loss survey measures every room and sets the final size.
| Floor area | 95 m² (from 3 bedrooms) |
|---|---|
| Outdoor design temperature | −3.0 °C (Heathrow) |
| Indoor temperature | 20 °C |
| Heat loss parameter | 2.10 W/m²K |
Get the size right before you get quotes
Adam measures every room on site, and your Blueprint sets the unit size, radiators and flow temperature.
Get My Free BlueprintHow we worked this out
- The sum: heat loss in kW = heat loss parameter × floor area × (indoor temperature minus outdoor design temperature) ÷ 1,000. The range runs 15% either side of that figure.
- Heat loss parameter: a rule-of-thumb figure in watts per m² of floor per degree, set by build era and insulation for a semi-detached house, then scaled by property type (detached ×1.10, bungalow ×1.15, end terrace ×0.95, mid terrace ×0.85, flat ×0.70).
- Outdoor design temperature: the MCS figure for your area, taken from CIBSE Guide A. That is −3.0 °C at Heathrow for Berkshire, Bucks, Surrey, west London and TW, −4.8 °C at Hurn for the south Hampshire coast and −4.6 °C at Brize Norton for Oxfordshire and Wiltshire. High ground takes off another 0.6 °C for each 100 m above the weather station.
- Indoor temperature: 20 °C for homes built before 2007 and 21 °C from 2007, based on the MCS room temperature defaults.
- Floor area from bedrooms: 50, 70, 95, 130 and 175 m² for one to five or more bedrooms.
- Sizes: the smallest common heat pump size, from 4 to 16 kW, that covers each end of the range.
- Left out: hot water, the loss from each room, ventilation and your radiators. A survey to BS EN 12831-1, the method the MCS standard MIS 3005-D sets for heat pump design, covers all of them.
Figures checked 11 November 2026.
Why the size matters
The Right Size Keeps Every Room Warm on the Coldest Day
A heat pump is sized to one number: the heat your house loses on a cold winter day, set at −3 °C for most of Berkshire and Surrey.
You may be wondering:
Will a unit that’s too small leave rooms cold in a January cold snap?
Will one that’s too big keep switching on and off through milder weather?
Could the wrong size push the running costs up?
How would I spot a quote with safety margins stacked on top?
Each of these comes back to the heat loss figure, which is why Adam measures your rooms before he names a size. Our guide to choosing a heat pump size covers what a wrong size costs you.
Online estimates
Why Online Heat Pump Sizing Calculators Tend to Guess High
A heat pump sizing calculator, ours included, works from averages for your build era and property type. It has no way to know about a cavity wall filled last year or an extension built to current regulations, so its answer carries a margin. Ours shows that margin as a range, 15% either side of the central figure.
How margins stack up
A 6 kW house, three safety margins later
Heat loss of the house
6.0 kW
Add 15% for hot water
6.9 kW
Add 15% for a cold bedroom
7.9 kW
Add 15% to be safe
9.1 kW
6.0 kW
What the house needs on a cold day
9.1 kW
The unit three margins later
Stack a few safety margins on top and the number climbs fast: a 6 kW heat loss turns into a unit of just over 9 kW, half as much again as the house needs.
Side by side
An online estimate next to Adam’s survey
Online estimate
Adam’s survey
Starting point
Averages for your build era and property type
Measurements taken in your own rooms
Recent upgrades
Can’t see a cavity filled last year or a new extension
Measured as the house stands on survey day
The answer
A range, 15% either side of the central figure
One figure, with the heat pump sized to the total for the house
Planned work
Sized for the house as it is today
Sized for the house as it will be once new windows or insulation are in
Follow the heat from the side wall to your shower
One unit outside heats the floors, the radiators and the hot water. Scroll to follow it room by room, then see the plan we draw up before any work starts.










- Lounge
- Kitchen and family
- Study
- Main bedroom
- Bedroom two
- Bathroom
Back to the wall, side to the path
It stands on anti-vibration feet on a concrete base, back to the wall, with its fans blowing out across the path, clear of the house. Two insulated pipes carry the heated water inside.
Two pipes, one sealed hole
The flow and return run insulated and clipped along the wall, then go through the brickwork side by side in one sealed sleeve. Heated water goes in through one and comes back through the other.
Warm floors, no radiators on the walls
The heated water runs through pipes under the floor, so the room holds a steady temperature all day. The thermostat by the door sets it.
The pipe is laid before the screed
It is clipped onto foil-faced insulation in a spiral. Warmer and cooler runs sit side by side, so the whole floor warms evenly.
Then the screed goes over it
A liquid screed is poured over the pipe and sets around it, so the floor itself holds the heat and gives it off.
Every floor loop starts and ends here
Each loop has its own flow meter, so every room can be balanced. Where the floor needs cooler water than the radiators, a blending valve and pump set its temperature.
Radiators sized for each room
A heat pump runs the water cooler than a boiler does, so each radiator is sized to the heat its room loses. Here that means a longer double-panel radiator under the window.
Double panels suit cooler water
Two steel panels with fins between them give off more heat from cooler water. The thermostatic valve on the end lets you set each bedroom on its own.
A cylinder the heat pump keeps hot
The two insulated pipes from the heat pump heat the stored water through a coil inside the cylinder. Mains water comes in through the valve group at the bottom, and each relief valve drains into its own tundish with a visible air gap.
One unit outside, the whole house warm
Floors downstairs, radiators upstairs and a cylinder of hot water, all run from the unit on the side wall.
Your Heat Pump Blueprint
We work out the heat every room needs, the size of heat pump that suits your house, and any radiator or floor changes. You see all of it before you commit.
Designed for your house
See every part of the system planned for your home
Your survey sizes the heat pump, the radiators or underfloor heating and the hot water cylinder for your rooms, with a fixed price before anything is ordered.
What Our Clients Say
Homeowners across Berkshire and the South East trust us with their heat pump installations.
The survey
On Survey Day, Adam Measures Every Room Before Anything Is Sized
Adam surveys and designs your system. He works the heat loss out room by room to BS EN 12831-1, the method MCS sets for heat pump design, and everything he finds goes into your Heat Pump Blueprint.
1
Room-by-room heat loss
Each room’s walls, windows, floor and ceiling go into its own calculation, and the heat pump is sized to the total for the house.
2
Radiator schedule
We check each radiator against its room at the design flow temperature. The schedule lists and prices any that fall short, so a swap can’t turn up later as an extra. Our guide to new radiators for a heat pump has the detail.
3
Flow temperature plan
This sets the design flow temperature and the weather compensation curve your system runs on. Where underfloor heating needs a different temperature from the radiators, mixing groups split the circuits.
4
Hot water plan
The plan sets the cylinder size for your household and where it sits, often the airing cupboard or loft when a combi leaves no hot water store.
5
Scope and fixed price
Unit, radiators, pipework, cylinder and controls sit under one fixed price, with the Boiler Upgrade Scheme grant, where your home qualifies, and what’s left to pay shown beneath it.
After the estimate
From a Rough Range to a Measured Design in Four Steps
Keep a note of your range. It gives us a starting point when you get in touch, and you can hold any quote you’re sent up against it.
Send Us Your Details
Send us a few details through the form below and we’ll book your survey.
Get My Free BlueprintSurvey Day
On survey day, Adam measures every room and checks the radiators, where the cylinder can go and where the outdoor unit can sit.
Design Walkthrough
After the survey, Adam takes you through the design on a video call: flow temperatures, room-by-room temperatures and anything we’d change.
Your Blueprint
Your Blueprint comes back with the unit size, a radiator schedule and an itemised quote you can compare line by line.
You’ll find the install itself, from survey to handover, on our air source heat pump installation page.
Aftercare
Our Guarantees for Your Heat Pump Installation
Every Eco Renewables heat pump installation comes with:
12 months of full support after installation
First annual service included with every installation
Insurance-backed deposit and 2-year workmanship cover
Manufacturer warranty on equipment
MCS consumer protection
See Examples of Our Work
Real air source heat pump and underfloor heating installations from our own jobs across Berkshire, Surrey and Buckinghamshire.
Heat pumps
Underfloor heating and hot water
Sizing calculator FAQs
Air Source Heat Pump Sizing Calculator FAQs
It gives a range 15% either side of a figure built from averages for your build era, property type and insulation. A house with a filled cavity or new glazing since it was built can sit outside that range. A survey measures yours room by room, so ask for your Blueprint when you want the real figure.
No, MCS installers have to size a heat pump from a room-by-room heat loss calculation, and the Boiler Upgrade Scheme only pays out on MCS-certified installs. Use this estimate to check the quotes you get, then book your survey with us.
The postcode sets the outdoor design temperature MCS uses for your area: −3.0 °C around Heathrow, which covers Berkshire, Bucks and Surrey, −4.6 °C in Oxfordshire and −4.8 °C on the south Hampshire coast. A colder design day means more heat to replace. Ask Adam to work out the figure for your address.
Tell us before the survey. Adam sizes the heat pump for the house as it will be, because a unit sized before new windows or wall insulation can end up too big once they’re in. Set insulation to Improved above to see the likely drop, then talk to us about timing.
A house losing that much heat needs a closer look. We’d check where insulation could bring the figure down first, then look at a larger unit or two units working together, and that call needs a survey. Send us your details and Adam will look at the house.
Yes. The fee covers the room-by-room measurements Adam takes on site. Book through the form below and we’ll confirm it when we arrange your visit.
Get Your Free Heat Pump Blueprint
Thinking about an air source heat pump? Tell us about your property and we will talk you through the options.
Heat loss of each room
Radiator sizes
Flow temperatures
Hot water plan
Get Your Heat Pump Sized From Your Own Rooms
Bring your range to the survey. Adam measures every room, sizes the heat pump to the total and puts the design and an itemised quote in your Blueprint.
Get My Free Blueprint