Accreditations and guarantees
MCS Certified Heat Pump Installer for Berkshire, Surrey and Buckinghamshire: Our Accreditations and Guarantees
The £7,500 Boiler Upgrade Scheme grant (if your home qualifies) and cover if an installer stops trading both depend on who fits your system. We’re an MCS certified installer for air source heat pumps, Gas Safe registered, approved by Grant, Vaillant, Panasonic and Stiebel Eltron, and Viessmann accredited. Where a public register exists, each credential below tells you how to check it.
From a homeowner who compared several installers before choosing us:
“I contacted a number of companies and had read up extensively on heat pumps before going ahead with Adam of Eco Renewables so I was confident in choice of installer, however you never really know if you have made the right decision until it’s all up and running and your home is no longer cold. Anyway two months in and the house is warm and the scop is looking good.”
Andrew Symes,
Google Review
Our credentials
MCS Accredited Installer for Heat Pumps: Every Credential We Hold
What each credential covers, and why it matters on your installation.
01
MCS Certified Heat Pump Installer
As an MCS heat pump installer we can apply for the Boiler Upgrade Scheme grant on your behalf and issue the MCS certificate for your system once it’s commissioned. Check it: search Eco Renewables Ltd on the MCS installer search.
02
Solar PV Design and Installation
We design and fit solar PV alongside our heat pump work. Adam surveys every solar job himself, our own electrician fits the system, and we handle the DNO application to your network operator.
03
Gas Safe Registered
Taking out a gas boiler means disconnecting a gas appliance, and the law allows only a Gas Safe registered business to do gas work. Check it: Gas Safe Register.
04
Manufacturer Approved Installer
Grant G1 installer, Vaillant approved installer and Viessmann accredited. Makers give 2 years as standard and up to 7 years on their own conditions. We register your heat pump with the maker and tell you which term applies.
05
Heat Geek Trained
Every system is designed by a Heat Geek trained engineer, starting from a room-by-room heat loss survey.
06
Insurance-Backed Deposit and 2-Year Workmanship Cover
If we ever stopped trading, an insurer would stand behind the deposit you’ve paid us and our workmanship for two years after installation.
Adam also ensured the grant application, planning and certification were all dealt with...
Stephen Saunders
Google Review
Grants and export payments
What Is MCS Certification, and What Does It Mean for Your Grant and Export Payments?
MCS, the Microgeneration Certification Scheme, sets the standards for designing and installing small renewable systems such as heat pumps and solar panels. MCS accreditation is how an installer proves it meets them, and two government schemes depend on it:
Heat pumps
Boiler Upgrade Scheme
£7,500 off an air source heat pump in England and Wales if you own the property, you're replacing gas, oil, LPG or electric heating, and an MCS certified installer fits it, applying to Ofgem for you so the grant comes off what you pay. New builds still with the developer don't qualify. Detail in our Boiler Upgrade Scheme grant guide.
Solar PV
Smart Export Guarantee
To be paid for the solar power you send to the grid, your installation and installer must be certified through MCS or an equivalent scheme, with a meter that records half-hourly exports. More on Smart Export Guarantee payments.
Manufacturer approvals
Vaillant and Grant Approved Heat Pump Installers in Berkshire
If you're comparing Vaillant heat pump installers in Berkshire, we fit as a Vaillant approved installer and as a Grant G1 installer, and we install Panasonic, Viessmann and Stiebel Eltron too. Some makers give a longer warranty when an approved installer fits and registers the unit, so the brand and model in your quote set your terms.
Brands we fit, each specified to match the design
Tighter budgets
Grant Aerona R290
Mid range
Vaillant or Panasonic
Premium end
Viessmann or Stiebel Eltron
Our Maidenhead case study shows our work as a Viessmann installer: a 13kW Vitocal 150. Compare the heat pump brands we fit before the survey if you already lean one way.
Deposit and workmanship
Insurance-Backed Guarantee Cover for Your Deposit and Our Workmanship
A deposit carries a risk you can't inspect on a survey visit: the installer going out of business before your job is finished, or a year or two after it. As an MCS installer we give an insurance-backed deposit and 2-year workmanship cover, so an insurer stands behind both:
Deposit paid, job not yet finished
Deposit protection
If an installer stopped trading after taking your deposit and before finishing the work, the insurance protects the money you'd paid.
Two years after installation
Insurance-backed workmanship guarantee
The workmanship cover deals with faults caused by the installation itself, and the insurance means the full two years are honoured even if the installer has ceased trading.
The manufacturer's warranty is a separate layer: it covers the heat pump, panels or inverter themselves, and we register it for you on every new heat pump.
Check before you sign
How to Check an MCS Installer's Credentials Before You Sign
Credentials show who may fit your system, and the Blueprint shows how we'd design it. For the questions on heat loss, design and aftercare worth asking at every survey, read our guide on how to choose a heat pump installer.
Three checks show whether any installer's claims hold up:
01
MCS
Search the company name or certification number on the MCS installer search.
02
Gas Safe
Look the business up on the Gas Safe Register before anyone disconnects your boiler.
Why Eco Renewables
Why Homeowners in Berkshire, Surrey and Buckinghamshire Choose Us
Room-by-room heat loss design
Our air source heat pump installation work sizes every radiator and underfloor loop for your coldest days.
A design call with Adam
After the survey, Adam takes you through the design on a video call: flow temperatures, room-by-room temperatures and anything we'd change.
Solar fitted to the same standard
Our solar PV installation jobs go up from scaffold on every pitched roof, with bird mesh round every array.
An information pack at the first visit
We leave you one on the system and how we work.
First annual service included
On every heat pump installation, with 12 months of full support after handover.
Based in Binfield
On the Berkshire and Surrey border, near Bracknell.
Follow the heat from the side wall to your shower
One unit outside heats the floors, the radiators and the hot water. Scroll to follow it room by room, then see the plan we draw up before any work starts.










- Lounge
- Kitchen and family
- Study
- Main bedroom
- Bedroom two
- Bathroom
Back to the wall, side to the path
It stands on anti-vibration feet on a concrete base, back to the wall, with its fans blowing out across the path, clear of the house. Two insulated pipes carry the heated water inside.
Two pipes, one sealed hole
The flow and return run insulated and clipped along the wall, then go through the brickwork side by side in one sealed sleeve. Heated water goes in through one and comes back through the other.
Warm floors, no radiators on the walls
The heated water runs through pipes under the floor, so the room holds a steady temperature all day. The thermostat by the door sets it.
The pipe is laid before the screed
It is clipped onto foil-faced insulation in a spiral. Warmer and cooler runs sit side by side, so the whole floor warms evenly.
Then the screed goes over it
A liquid screed is poured over the pipe and sets around it, so the floor itself holds the heat and gives it off.
Every floor loop starts and ends here
Each loop has its own flow meter, so every room can be balanced. Where the floor needs cooler water than the radiators, a blending valve and pump set its temperature.
Radiators sized for each room
A heat pump runs the water cooler than a boiler does, so each radiator is sized to the heat its room loses. Here that means a longer double-panel radiator under the window.
Double panels suit cooler water
Two steel panels with fins between them give off more heat from cooler water. The thermostatic valve on the end lets you set each bedroom on its own.
A cylinder the heat pump keeps hot
The two insulated pipes from the heat pump heat the stored water through a coil inside the cylinder. Mains water comes in through the valve group at the bottom, and each relief valve drains into its own tundish with a visible air gap.
One unit outside, the whole house warm
Floors downstairs, radiators upstairs and a cylinder of hot water, all run from the unit on the side wall.
Your Heat Pump Blueprint
We work out the heat every room needs, the size of heat pump that suits your house, and any radiator or floor changes. You see all of it before you commit.
Designed for your house
See every part of the system planned for your home
Your survey sizes the heat pump, radiators or underfloor heating and the hot water cylinder from a room-by-room heat loss calculation, with a fixed price before anything is ordered.
Aftercare
Our Guarantees as an MCS Certified Installer
12 months of full support after handover
First annual service included with every heat pump installation
Insurance-backed deposit and 2-year workmanship cover
Manufacturer warranty registered on every new heat pump
MCS consumer protection
MCS consumer protection means you can take a complaint to MCS if a problem with your installation isn't put right.
Case study: Maidenhead
Real Clients. Real Results.
13kW
Viessmann Vitocal 150
21°C
Consistent throughout
2
Flow temperatures via mixing groups
UFH
Underfloor upstairs plus radiators
A 1960s house in Maidenhead had mixed insulation, so heat loss varied a lot from room to room, and the upstairs underfloor heating had to fit tight floor heights using pre-routed chipboard panels. We fitted a 13kW Viessmann Vitocal 150 with mixing groups running two flow temperatures and hydraulic separation. The house now holds a steady 21°C throughout, with no cold spots.
"The temperature is consistent throughout and we can fine-tune it easily. It feels engineered, not just installed."
Homeowner, Maidenhead
See Examples of Our Work
Real air source heat pump and underfloor heating installations from our own jobs across Berkshire, Surrey and Buckinghamshire.
Heat pumps
Underfloor heating and hot water
MCS installer FAQs
Questions About Choosing an MCS Certified Installer
An MCS certified installer has passed an assessment against the Microgeneration Certification Scheme standards for heat pumps, solar panels and similar systems, and appears on the MCS register. Search Eco Renewables Ltd on the register to check ours, which covers heat pumps.
Yes. We design and fit solar PV, working from scaffold on every pitched roof. The Solar Design Pack sets out panel layout, predicted generation and itemised cost before anything is ordered.
Yes. The £7,500 grant for an air source heat pump in England and Wales needs an MCS certified installer, who applies to Ofgem for you. You must also own the property and be replacing gas, oil, LPG or electric heating. Since 28 April 2026 you no longer need an EPC to apply. We confirm whether your home qualifies at the survey.
We fit Vaillant heat pumps as an approved installer. We choose the model and size from your heat loss design.
It's a guarantee with an insurer behind it, so its full term is honoured even if the company that gave it stops trading. We give an insurance-backed deposit and 2-year workmanship cover, and we'll go through it with you at the survey.
Yes, and you can check us on the Gas Safe Register. On a boiler-to-heat-pump job it matters because only a registered business may disconnect and make safe the old gas boiler.
Get a Heat Pump Survey for Your Home
Tell us about your property and we will talk through your air source heat pump options with you.
Heat loss of each room
Radiator sizes
Flow temperatures
Hot water plan