Do solar panels work in winter in Berkshire and Surrey? Yes, at a little over a quarter of their June rate. The EU’s PVGIS model gives that shape for a south-facing Reading roof from 19 years of satellite weather, cloud included. At the 850 to 950 kWh per kWp a year we plan with, a 4kWp array makes about 4 kWh a day in December against 14.5 in June.
Two roofs on the same street can give very different winter results. Point the same 4kWp array east instead of south and PVGIS puts it 4 percent behind in June and at 43 percent of the south-facing output in December. Pitch and shading, both settled before the panels go up, close part of that gap.
Panels turn daylight into electricity, so they produce whenever light reaches the glass, frost or no frost. Winter takes away day length and sun height. At Reading’s latitude the midday sun stands about 62 degrees above the horizon at the June solstice and about 15 degrees at the December solstice, so its light arrives at a shallow angle through more air.
About 15 degrees
Height of the midday sun at the December solstice at Reading’s latitude, against about 62 degrees at the June solstice.
PVGIS counts the sunlight landing on the panel itself. A 35-degree south-facing roof near Reading receives about a quarter as much sunlight per square metre in December as in June. Electricity output follows that light: on the 900 kWh per kWp basis, the 4kWp array makes about 436 kWh in an average June and 123 kWh in an average December.
Cold works in your favour. Manufacturers rate panels at a cell temperature of 25°C, and REC’s Alpha Pure-R datasheet gives a linear power coefficient of 0.24 percent per degree, so the same panel gains output as its cells cool below that point. A bright frosty morning in Bracknell or Guildford loses nothing to temperature; the shorter day, the lower sun and the heavier winter cloud account for the drop.
The table models one roof: 4kWp of crystalline panels facing due south at a 35-degree pitch near Reading. PVGIS supplies each month’s share of the year. It models an ideal unshaded roof, so we scale those shares to 900 kWh per kWp, the middle of our 850 to 950 kWh planning range. Enter your own postcode, pitch and direction on the same tool to compare the shape.
| Month | Share of the year (PVGIS) | Average output per day | Month total |
|---|---|---|---|
| January | 4.0% | 4.7 kWh | 145 kWh |
| February | 5.2% | 6.6 kWh | 186 kWh |
| March | 8.5% | 9.8 kWh | 305 kWh |
| April | 11.2% | 13.5 kWh | 405 kWh |
| May | 12.0% | 13.9 kWh | 431 kWh |
| June | 12.1% | 14.5 kWh | 436 kWh |
| July | 12.2% | 14.2 kWh | 439 kWh |
| August | 10.9% | 12.7 kWh | 393 kWh |
| September | 9.3% | 11.1 kWh | 334 kWh |
| October | 6.6% | 7.7 kWh | 239 kWh |
| November | 4.6% | 5.5 kWh | 164 kWh |
| December | 3.4% | 4.0 kWh | 123 kWh |
| Year | 100% | 9.9 kWh | 3,600 kWh |
December is the weakest month and also the least predictable one: PVGIS puts its year-to-year spread at about 22 percent either side of its average, so a grey December can fall well short of the table. At a survey for solar panel installation in Reading, we swap the model roof for your real pitch, direction and shading.
Ask for your own roof’s month-by-month figures at a Solar Design Pack survey, and judge the design on its December row as well as its yearly total.
“He has made himself available at short notice to answer any of my stupid questions, of which there were a lot. Would highly recommend.”
Ben Finnie, ⭐️⭐️⭐️⭐️⭐️ Google Review
Each kind of winter weather leaves its own mark on the output figures, and shade is the one you can design around before installation:
Midday shadow of a 10-metre tree
June
About 5 metres
December
About 37 metres
Pitch counts for more in winter too. PVGIS gives the south-facing array near Reading about 22 percent less December output at a 20-degree pitch than at 35 degrees and about 15 percent more at 50 degrees, while the steeper roof gives up 1 percent across the year. When we plan a solar PV installation for winter, we check shading at the December sun angle before placing a single panel.
A heat pump draws hardest on the meter in December and January, when the Reading roof averages about 4.0 and 4.7 kWh a day. Your heat loss calculation gives the house’s cold-day heat demand in kW; divide it by the heat pump’s COP at that temperature for its electricity draw. Put a day of that draw beside the December row to see the share of midwinter heating solar can carry.
Take the cold-day heat demand
Your heat loss calculation gives the house’s cold-day heat demand in kW.
Divide by the heat pump’s COP
Use the COP at that temperature to get the electricity draw.
Set a day of that draw beside December
The Reading roof averages about 4.0 kWh a day in December, so the comparison shows the share solar can carry.
The sums improve either side of winter: spring and autumn output covers more of a lighter heating load, and from April to September a heat pump scheduled to heat the hot water cylinder in daylight can run on the roof’s surplus. Our guide to pairing a heat pump with solar panels sets out how the two divide the work by season.
On one combined job, we fitted the heat pump and Leon Shead’s company fitted the solar PV, and sized the array to match it.
If a heat pump is part of your plan, bring its numbers to the Solar Design Pack survey so the array is sized against the winter load as well as the summer one.
“Eco Renewables recently installed a heat pump for my customer and aligned it perfectly with my company’s solar PV system. By working together, we were able to size the solar PV accordingly and deliver a seamless, efficient setup.”
Leon Shead, ⭐️⭐️⭐️⭐️⭐️ Google Review
A battery does most of its work in summer, holding the afternoon surplus for the evening. On an average December day the Reading roof makes about 4 kWh, and a household at home through daylight uses much of that as it arrives, which leaves the battery little solar to store in midwinter.
A time-of-use tariff fills that gap. Charge the battery in your supplier’s cheap overnight window and it can run the house through the evening peak in January as it does in July, with the panels topping it up on brighter winter days. Suppliers set and revise both the window and the rates, so read the current terms before you count on a saving.
The payback sum for storage on your own tariff is a separate calculation, covered in the case for and against a solar battery.
Yes. Cloud scatters daylight, and panels generate from that diffuse light at a lower rate than in direct sun. On PVGIS’s monthly shape, scaled to 900 kWh per kWp a year, a south-facing 4kWp roof near Reading averages about 4 kWh a day in December, with 19 winters of real cloud already counted.
A thin layer lets some light through, and a full covering stops most output until the snow melts or slides off the pitched glass. Leave it to clear by itself: climbing onto a frosty roof to brush panels risks a fall for a few kWh.
A 440W panel facing south at 35 degrees near Reading makes about 0.44 kWh a day in December and 0.51 kWh in January, on PVGIS’s monthly shape scaled to 900 kWh per kWp. The same panel averages about 1.6 kWh a day in June and 396 kWh across the year, inside the 375 to 420 kWh a 440W panel gives in the South East.
No. Panels need daylight, so output stops at dusk and starts again at dawn. Evening and overnight use comes from the grid or from a battery charged earlier in the day or in a cheap overnight tariff window.
They can be, because savings count across the year: about 68 percent of the Reading roof’s yearly output arrives between April and September. Summer output cuts bills when you use it, and the right number of panels for your roof decides how much winter use it covers.
For a south-facing 4kWp array at 35 degrees, a December day near Reading averages about 4 kWh. PVGIS puts Bracknell’s December 1 to 2 percent above Reading’s and Guildford’s about 5 percent below. Across Berkshire and Surrey, pitch, direction and shade move the December figure far more than the town does.
A yearly total on a quote tells you little about January. Ask for your roof’s output month by month, worked from its real pitch, direction and December shading, then compare every quote on its winter rows as well as its annual figure. The Solar Design Pack survey is the place to ask for those numbers.
Eco Renewables are trusted by homeowners throughout Berkshire, Surrey, and the South East to provide high-quality solar system installations.
If you're considering a heat pump, the survey is where it starts. We assess the property, run the heat loss calculations, and tell you exactly what the system would look like.