Solar
Solar Panel Efficiency on Berkshire and Surrey Roofs: What the Percentage Means in kWh, and When It Matters
By Adam Dare
Heat Geek trained installer
Updated 24 November 2026
Reading time
🎉 Named South East Heating Installer of the Year 2026
Solar panel efficiency is the share of the sunlight landing on a panel that it turns into electricity, and silicon panels from the ten largest makers averaged 22.7% in late 2024, with the best at 24.8%. For homeowners in Berkshire and Surrey comparing quotes, including owners of an east-west or part-shaded estate roof, the roof decides more of the yearly total than the datasheet rating.
The rating measures watts per square metre of glass. Your roof sets the rest: which way each slope faces, the trees along the boundary and how hot the cells run in July. The worked figures here come from PVGIS, the European Commission’s solar model, run for a Bracknell roof on 24 November 2026.
Every panel is rated under standard test conditions: sunlight of 1,000 watts per square metre, cells held at 25°C and a fixed light spectrum. Efficiency is the rated power divided by the sunlight falling on the panel’s area. A 1,762 by 1,134 mm panel, about 2 square metres, converts 22.0% of that light if it is rated at 440 W, and 24.0% at 480 W.
1,000 watts per square metre
Sunlight on the panel under standard test conditions
25°C
Cell temperature under the same test, with a fixed light spectrum
A panel sold in the UK carries the same rating as the identical panel sold in southern Spain, because the test conditions are fixed. Solar panel efficiency in the UK is that same datasheet figure. A Berkshire roof gets less light than a Spanish one and its cooler cells win a little back, so the same 22% panel makes fewer kWh a year in Berkshire.
Silicon cells made up about 98% of world panel production in 2025, and Fraunhofer ISE’s July 2026 report counts 86% of those wafers as n-type, with TOPCon cells now dominant. The report names TOPCon and heterojunction cells as the replacements for older p-type PERC cells. Back-contact cells move all the wiring to the rear, so no metal strip shades the front of the cell.
From the lab to the roof: silicon panel efficiency
Lowest commercial module in the top-ten makers’ range
18.9%
Shipment-weighted average, late 2024
22.7%
Highest commercial module in the same range
24.8%
Best laboratory module
26.0%
Best laboratory cell
28.1%
Source: Fraunhofer ISE, Photovoltaics Report, updated 14 July 2026 (commercial figures from top-ten makers’ datasheets available in September 2025).
The most efficient solar panels on sale for houses today sit close to the 24.8% at the top of Fraunhofer’s range. On two current datasheets, TOPCon panels ran from 22.0% to 24.0%, and pv magazine reported a back-contact panel in June 2026 at 23.8% to 24.7%. Laboratory records of 26.0% for a module and 28.1% for a single cell show how much headroom factory panels still have.
Put a kWh Figure Beside Each Rating
If two quotes name panels a point or two apart, a Solar Design Pack gives you the yearly kWh for your own roof to set beside them.
“I contacted a number of companies and had read up extensively on heat pumps before going ahead with Adam of Eco Renewables so I was confident in choice of installer, however you never really know if you have made the right decision until it’s all up and running and your home is no longer cold.”
Andrew Symes, Google Review
Efficiency sets how many watts fit; each watt on a given slope collects the same light. PVGIS, run for an unshaded south-facing Bracknell roof at a 35° pitch with standard 14% system losses, predicts 1,021 kWh a year from each kWp. It models open sky, with no trees, chimneys or next-door roofs, so we design on 850 to 950 kWh per kWp. The table’s 9% gap holds at either figure.
| 22.0% panels, 440 W each | 24.0% panels, 480 W each | |
|---|---|---|
| Panel size | 1,762 x 1,134 mm | 1,762 x 1,134 mm |
| Small roof, room for 8 panels | 3.52 kWp | 3.84 kWp |
| Yearly kWh in PVGIS, unshaded, south at 35° | 3,595 kWh | 3,921 kWh |
| Yearly kWh in PVGIS, same 8 panels split east-west | 2,853 kWh | 3,112 kWh |
| Panels needed for 3.84 kWp on a bigger roof | 9 (3.96 kWp) | 8 |
On that small roof the 24.0% panels lift the yearly figure from 3,595 to 3,921 kWh, about 9% more. Turned east-west, the same eight panels fall by about a fifth, to 2,853 and 3,112 kWh, so a 22.0% array facing south beats a 24.0% array split east-west. Our guide to how solar panels perform in winter covers the dark months inside these yearly totals.
A higher rating earns its place when roof space runs out before you reach the system size you want. That tends to happen on these roofs:
Roofs where space runs out first
On a large south-facing roof the case is weaker: nine 440 W panels give 3.96 kWp, more than eight 480 W panels, so one extra standard panel closes the gap. Every solar PV installation we price starts from a drawn layout of your slopes, with the panel and its rating named in the itemised quote, so you can see which side of that line your roof sits.
See Which Panels Fit Your Slopes
A Solar Design Pack draws the panels onto each slope of your roof and states the yearly kWh they should generate.
“He is very knowledgeable in this area and clearly explained the benefits of installing a heat pump, along with the options available and the steps that would be involved.”
Ben Finnie, Google Review
Panels lose power as they warm. Each datasheet gives a temperature coefficient, the share of rated power lost for every degree the cells run above 25°C. In one datasheet’s nominal operating test, with 800 watts per square metre of sun, 20°C air and a 1 m/s breeze, the cells settled at 43°C, which costs 4.7% to 5.2% of rated power across the coefficients below.
-0.26% to -0.29% per °C
Power lost for each degree a cell runs above 25°C, across the two datasheets read for this guide on 24 November 2026.
Shade can cost far more. A shadow from a chimney or tree across a few cells limits the current through that section of the panel, and bypass diodes (three per panel on one datasheet read here) let the current skip the shaded third. Roof direction is the larger lever again, and our guide to how many panels your roof needs works through orientation and shading slope by slope.
Panels also lose a little power each year of their working life, and our guide to how solar panels age covers that alongside panel warranties.
Surrey County Council describes Surrey as England’s most wooded county, with woodland on around 24% of its land against a 10% national average. An oak or pine at the end of a garden can shade a rear slope through the low-sun months, and no panel rating wins that light back.
Woodland cover, share of land
Surrey
around 24%
National average
10%
Source: Surrey County Council
On a house around Bracknell, Wokingham or Camberley with a hipped roof, dormers or an east-west split, space runs out early and a higher-rated panel is more likely to pay its way. On a conservation-area street, an Article 4 Direction can remove the permitted development right for front-slope panels, which can leave the rear slope as the only option; the survey checks whether one applies.
Our page on solar panel installation in Camberley sets out how a Design Pack works for homes there, from the survey of the roof to the itemised price.
Design Around Your Trees and Slopes
A Solar Design Pack works from the shade, pitch and direction of each slope on your Berkshire or Surrey roof before it puts a yearly kWh figure in writing.
“We have been customers of Adam for over 5 years and he has never failed us yet!”
Adam Hewitt, Google Review
A rating of 22.7% or more puts a panel at or above the market average, the late-2024 shipment-weighted figure for the ten largest makers in Fraunhofer ISE’s July 2026 report. Panels near the top of their 18.9% to 24.8% range suit tight roofs; on a roof with space to spare, the yearly kWh counts for more than the last point.
The same as anywhere else, because every rating comes from one fixed test. The UK difference is sunshine: PVGIS predicts about 1,021 kWh a year per kWp for an unshaded south-facing roof in Bracknell at 35°. Real roofs lose some of that to shade the model leaves out, so we plan on 850 to 950 kWh per kWp.
On a small or broken-up roof they often are, because they put more kilowatts on the space you have: eight 24.0% panels give 3.84 kWp where eight 22.0% panels give 3.52 kWp. On a large south-facing roof, one extra standard panel closes the gap.
Yes. On the two datasheets read for this guide, panels lose 0.26% to 0.29% of rated power for every degree the cells run above 25°C. Cells at 43°C, the nominal operating figure on one datasheet, give up 4.7% to 5.2%, so a bright, cool day gets more from each unit of sunlight than a hot one.
It can matter more there, because each slope often holds only a few panels and a higher rating is the only way to fit more watts on it. In the Bracknell example, eight 24.0% panels split east-west generate 3,112 kWh a year against 2,853 kWh for 22.0% panels.
The rating stays the same; the yearly total depends on your roof. In PVGIS, an unshaded east-west split in Bracknell makes about 810 kWh per kWp a year against 1,021 facing south, and tree shade on a rear slope in Berkshire and Surrey can take more off.
Ask for a Solar Design Pack and you get the layout for each slope, the predicted yearly kWh and an itemised price with the panels named, ready to set beside any other quote.
Eco Renewables are trusted by homeowners throughout Berkshire, Surrey, and the South East to provide high-quality solar system installations.
If you're considering a heat pump, the survey is where it starts. We assess the property, run the heat loss calculations, and tell you exactly what the system would look like.
Get My Free Solar Design Pack